Free checklist

Before your best person retires: a knowledge transfer checklist

Most of what experienced people know was never written down. This checklist helps you get it out of their head and into a form the next person can use, starting months before their last day. Print it, or work through it with them.

1. Three to six months before

  • Tell them early why you're doing this: what they know matters to the people who stay.
  • List the equipment, places, customers and jobs they know best.
  • Ask the people around them what they always go to them for, and add the answers to the list.
  • Pick one person to learn from them, and put time for it on both their schedules.

2. Capture it while they work

  • Have them talk through a job while they do it, not in a meeting room. One topic at a time, a minute or two each.
  • Start with what goes wrong: the faults they've fixed and the tricks that aren't in the manual.
  • Get the settings, measurements and part numbers they really use, and where things are kept.
  • Take photos of nameplates, labels, setups and the parts they mean.
  • File each note under the machine, unit or place it's about, so the next person finds it there.

3. The things only they know

  • Which customers, suppliers or inspectors need special handling, and who to call.
  • The jobs only they do, and what happens today when they're away.
  • The mistakes they've seen others make, and how to avoid them.
  • What they would tell their replacement on the first day.

4. Check and hand over

  • Have the person taking over go through each note and ask follow-up questions while there's still time.
  • Have a second experienced person check the notes and flag anything wrong or out of date.
  • Put the notes a new person needs first in order, as a training list.
  • Ask whether you may contact them after they leave, for the questions nobody thought of.

5. After they leave

  • When a question comes up that the notes don't answer, record the answer once it's found, so nobody has to ask again.
  • Go over the notes on your most important equipment from time to time and update what changed.

Questions to ask, by trade

Use these as prompts. Ask one at a time, at the equipment or place it's about, and record the answer.

Machine shops & fabrication

  • Which jobs only run right on one machine, and why?
  • What do you do on our repeat parts that isn't on the setup sheet?
  • Which machines have quirks, like a warm-up routine, backlash or a probe that drifts?
  • What do you check before you trust a first article?
  • Which materials have given us trouble, and what fixed it?
  • Which customers have requirements that aren't on the print?
  • Which fixtures or tools did we make ourselves, and how do you set them up?
  • Which alarms can an operator clear, and which ones need you?

KeptLabs for Machine shops & fabrication

Manufacturing

  • Which lines make scrap on second shift but not first, and why?
  • What is the real order of a changeover on our oldest press, not the one on the work instruction?
  • Which sensors or feeders need a nudge, and how do you tell it's about to act up?
  • Which suppliers' lots do you watch, and what do you look for when a coil or resin arrives?
  • Which first-article dimensions drift, and which ones does the customer really look at?
  • What have you seen new operators do that cost us a shift of scrap?
  • Which customers want packaging or labeling that isn't on the routing?
  • What do you tell the next shift in the hallway that never goes on the handover sheet?

KeptLabs for Manufacturing

Plant & industrial maintenance

  • Which machines are older than their manuals, and what has been rewired over the years?
  • What do you check first when the main compressor won't load?
  • Which breakdowns keep coming back, and what is the real cause behind them?
  • Which parts cross-reference to something easier to get, and which look right but are wrong?
  • Where are the lockout points that aren't labeled or are hard to find?
  • Which vendor techs actually know our controllers, and how do you reach them at night?
  • What shortcuts have you seen people take that nearly hurt someone?
  • What do you listen for on your walk-around that tells you something is about to fail?

KeptLabs for Plant & industrial maintenance

Facilities maintenance

  • Which zones are always too hot or too cold, and what actually fixes them?
  • What is the right order to bring the chillers and boilers back after a shutdown?
  • Which tenants are touchy about noise, notice or temperature, and how do you handle them?
  • Where are the shutoffs and cleanouts that are not on the as-builts?
  • How do you switch the building from heating to cooling, step by step?
  • Which doors, locks and keys cause trouble, and who really holds them?
  • What does the building automation screen show that misleads people?
  • Which contractors do good work in our buildings, and which ones need watching?

KeptLabs for Facilities maintenance

Mining

  • What sounds tell you a crusher or a screen is about to give trouble?
  • Which trucks or loaders have quirks that new operators do not know about?
  • Where does the conveyor track off, and how do you correct it safely?
  • What have you seen go wrong with ground or road conditions in a bad season?
  • In what order do you isolate and lock out our main conveyor?
  • Which chutes hang up, and what actually frees them?
  • Which vendor techs know each machine, and what should we send them first?
  • What do you tell the incoming shift that is not in the handover book?

KeptLabs for Mining

Construction

  • What did each inspector ask for that is not in the code book?
  • What went wrong on the last job like this one, and how did you fix it?
  • Which subs do you trust with a tight schedule, and which ones need a nudge?
  • In what order do you sequence rough-ins to avoid tearing out finished work?
  • Which long-lead items bite us if we forget to order them early?
  • Which sites had access problems, like gate codes, neighbors or tight streets?
  • Which of our lifts or generators have quirks that only the old hands know?
  • What do you photograph before covering up, and why?

KeptLabs for Construction

HVAC & refrigeration

  • Which rooftop units trip on high head pressure in summer, and what do you do about it?
  • What does that flash code really mean on the old boards, and what do you check first?
  • Which charges differ from the nameplate on units you have serviced for years?
  • Where do the leaks usually turn up on our refrigeration racks?
  • Which sites have access problems, like a locked roof, a back stairwell or a gate?
  • Which controls or thermostats cause callbacks, and how do you set them up?
  • Which customers can't lose cooling during business hours, and what do you do for them?
  • Which parts cross-reference to something easier to get, and which cross-references fail?

KeptLabs for HVAC & refrigeration

Electrical

  • Which buildings have panel schedules or as-builts that don't match what is really behind the wall?
  • What does each local inspector or AHJ insist on that isn't in the code book?
  • Which circuits are back-fed or shared in ways nobody would guess?
  • What do you do on a service upgrade to avoid surprises with the utility or the inspector?
  • Which breakers or panel types give us nuisance trips, and what actually stops them?
  • Where are the junction boxes and disconnects that are buried above ceilings or behind equipment?
  • Which customers can't lose power at all during business hours, and how do you plan around them?
  • What have you seen an apprentice assume was dead that wasn't?

KeptLabs for Electrical

Plumbing

  • Which buildings have shutoffs that don't fully close, and how do you work around them?
  • Which drains clog again and again, and what is the real cause behind each one?
  • What does the camera usually show in our oldest buildings that people misread?
  • Which fixtures or valves look right but don't fit, and what do you use instead?
  • What does each inspector want that isn't spelled out in the plumbing code?
  • Which customers need a call before the water goes off, and where do you park and get in?
  • Where do you find pressure problems or frozen lines in winter, and what do you do about them?
  • What have you seen a new plumber do that flooded a floor?

KeptLabs for Plumbing

Gas piping

  • How does each inspector want to see a pressure test, and what got a red tag before?
  • Which regulators or meter sets have quirks with venting or placement?
  • How do you coordinate with the gas utility so a job doesn't stall waiting on them?
  • What mistakes have you seen with bonding, sediment traps or drip legs?
  • Which appliances are hard to connect, and what connectors or adapters actually work?
  • What do you check that isn't on the permit before you call for inspection?
  • Which jobs have access problems, such as gates, dogs, tight meters or neighbors?
  • What do you never let a new fitter do before the line has been tested?

KeptLabs for Gas piping

Field service

  • Which customers' equipment fails the same way over and over, and what is the real fix?
  • Which fault codes mean something different from the manual on a given model?
  • Which parts do you always carry because the first visit fails without them?
  • Which sites have rules that aren't on the work order, like badges, hours or escorts?
  • Which customers need special handling, and what makes them upset?
  • What do you do on a return visit that you skip on a first visit?
  • Which firmware versions or settings cause trouble on our installed equipment?
  • What do you say to the customer when a repair isn't finished?

KeptLabs for Field service

Utilities

  • Where are mains, valves and services buried that the old system maps have wrong or don't show?
  • In what order do you isolate and restore a section in an outage, and who has to be told?
  • Which stations alarm in every storm, and what do you look at first when they do?
  • Which pumps air-lock or hang up, and what actually clears them?
  • Which roads or stations can't be reached after heavy rain?
  • Who at the neighboring utility, the county or the contractors do you call first, and what do you tell them?
  • What do you do on a storm call-out that nobody writes down?
  • What have you seen go wrong when someone trusted the SCADA screen too much?

KeptLabs for Utilities

Energy & renewables

  • Which inverters fault at sunrise or at sunset, and how long do you wait before you roll a truck?
  • Which fault codes mean something other than what the manufacturer says?
  • Which combiner boxes or strings keep coming back with the same problem?
  • Which turbines have yaw, pitch or gearbox quirks that new techs wouldn't notice?
  • Which battery alarms are sensors, and which ones are real?
  • Which roads or gates wash out or lock up, and who do you call?
  • Which vendor techs know our equipment, and what do you tell them first?
  • What have you seen a new tech do around live equipment that worried you?

KeptLabs for Energy & renewables

Oil & gas / pipelines

  • What is the real startup and shutdown sequence at our oldest station, as opposed to the procedure?
  • Which compressors trip in summer, and what do you check before they do?
  • Which valves take two people or a trick to seat, and which ones leak by?
  • Where on the line do pigs hang up, and what do you do when they do?
  • Which lease roads or right-of-way gates are a problem, and who do you call?
  • What do you tell the next rotation that doesn't go in the log?
  • What have regulators or inspectors asked about that surprised us?
  • What have you seen new operators do that nearly caused an incident?

KeptLabs for Oil & gas / pipelines

Do it with voice notes

KeptLabs is built for the "capture it while they work" part: they talk for a minute at the machine or on the site, and it's written up, filed under the right equipment or place, and searchable by the whole team.

How it works